Skip to main content
Skip table of contents

VCOM import compatibility list

Last modified:

About the VCOM import compatibility list

meteocontrol is directly compatible with many manufacturers, allowing you to import your measured values directly into VCOM Cloud and monitor your systems remotely via VCOM Monitoring. This import compatibility list provides an overview of the data sources and functions we support.

In general, VCOM supports the following for all data sources:

  • Data logger monitoring: Data is displayed in charts and portlets, and reflected in alarms. See Data outage alarms and Communication loss alarms.

  • For each system, it is possible to have multiple data loggers and data logger types. Exception: very old data sources.

  • Historic data import into VCOM from other data sources, provided the files are available. This is subject to a one-time fee. Contact Support for more information.

  • The Data logger overview portlet allows you to:

    • View the status of data transfer to VCOM.

    • Download raw data.

For general guidelines on configuration in VCOM, see Data sources/data logger. Specific instructions are available for selected data sources.

Notes

Please note that the actual data collected may vary due to the local hardware or configuration.

Data sources marked with an asterisk* are available upon request.

Manufacturer/Type

Import data

Portal integration

Further information

Measuring interval

meteocontrol blue’Log X-Series

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Remote control system

(tick) Energy trading

(tick) Battery system

(tick) Meter/power analyzer

(tick) Tracker

(tick) Device events

(tick) HTTP/ Rest-API

Data format: XML

(tick) Remote access

(tick) Live access charts

(tick) Live access configuration

(tick) Encrypted connection

(tick) Configuration via portal

Import configuration: blue'Log XM/XC data logger

5/10/15 min

meteocontrol Import interface V2

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Remote control system

(tick) Energy trading

(tick) Battery system

(tick) Meter/power analyzer

(tick) Tracker

(tick) Device events

(tick) Import configuration

(tick) HTTP/ Rest-API

(tick) FTP

Data format: XML

Import configuration: Import interface V2

5/10/15/30/60 min

meteocontrol WEB’Log

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Remote control system

(tick) Energy trading

(tick) Battery system

(tick) Meter/power analyzer

(tick) Tracker

(tick) HTTP/ Rest-API

(tick) Email

Data format: TXT/CSV

(tick) Remote access

(tick) Configuration via portal

Import configuration: WEB’log data logger

5/10/15 min

ABB Aurora Vision API

(tick) Inverters

(tick) HTTP/ Rest-API

Data format: JSON

Import configuration: ABB Aurora Vision API

5/15 min

AE SiteLink

(tick) Inverters

(tick) Weather sensors

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

10 min

AlsoEnergy API

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) HTTP/ Rest-API

(tick) Configuration via portal

5 min

Campbell

(tick) Weather sensors

(tick) FTP

Data format: TXT/CSV

5/10/15 min

Capfile

(tick) Meter/power analyzer

(tick) FTP

Data format: XML

5/10/15 min

Chint API

(tick) Inverters

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

5/10 min

Enedis API

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

Import configuration: VCOM Enedis API

5 min

Field logic API

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

5/10/15 min

Fronius Datamanager 2.0

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) FTP

Data format: JSON

Import configuration: Fronius Datamanager 2.0

5/10/15 min

Fronius Solar.web API

(tick) Inverters

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

Import configuration: Fronius Solar.web API

5 min

Fudura Telemetry API

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

15 min

GoodWe API

(tick) Inverters

(tick) HTTP/ Rest-API

Data format: JSON

(tick) Encrypted connection

5 min

Growatt API

(tick) Inverters

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

5 min

Huawei FusionSolar API

(tick) Inverters

(tick) Weather sensors

(tick) Battery system

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

Import configuration: HUAWEI FusionSolar API

5 min

Huawei Smartlogger 1000/2000/3000

(tick) Inverters

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) FTP

Data format: CSV

Import configuration: HUAWEI SmartLogger 1000/2000/3000

5/10/15 min

i-less API

(tick) Inverters

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

5/10/15 min

iPLON

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) HTTP/ Rest-API

Data format: XML

5/10/15 min

Joulz API

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

15 min

KACO XP100 Powador series

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Email

Data format: TXT/CSV

This product is discontinued by the manufacturer, but can still be used.

Import configuration: KACO blueplanet

5 min

KACO blueplanet TL series (KACO direct)

(tick) Inverters

(tick) HTTP/ Rest-API

Data format: TXT/CSV

Import configuration: KACO blueplanet TL series (KACO direct)

5 min

KACO blueplanet NX series

(tick) Inverters

(tick) HTTP

Data format: XML

Encrypted connection

Import configuration: Import interface V2

5 min

Kenter Metering Data API

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

5 min

KOSTAL Piko

(tick) Inverters

(tick) HTTP/ Rest-API

Data format: TXT/CSV

Import configuration: KOSTAL Piko inverter

5/10/15 min

Laplace API

(tick) Inverters

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

5/10/15 min

LTi PV-Master I & II

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) FTP

Data format: TXT/CSV

Import configuration: LTi PV-Master I/II

5 min

Obvius AcquiSuite*

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) HTTP/ Rest-API

Data format: TXT/CSV

5/10/15 min

Phoenix Contact IIc

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Battery system

(tick) Meter/power analyzer

(tick) Tracker

(tick) HTTP/ Rest-API

Data format: XML

Import configuration: Phoenix contact data logger

5 min

Raptech API

(tick) Inverters

(tick) HTTP/ Rest-API

Data format: JSON

15 min

Seegma API

(tick) Inverters

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

5/10/15/30/60 min

Seinon API

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

(tick) Encrypted connection

(tick) Configuration via portal

15 min

Skytron Skycontrol

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Remote control system

(tick) Meter/power analyzer

(tick) FTP

Data format: XML

1/5/15 min

SMA Webbox Cluster Controller

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick)
Meter/power analyzer

(tick) FTP

Data format: CSV/XML

Import configuration: SMA Webbox / Cluster controller

5 min

SMA Data Manager M

(tick) Inverters

(tick) Weather sensors

(tick) Remote control system

(tick) Meter/power analyzer

(tick) Battery system

(tick) FTP

Data format: XML

Import configuration: SMA Data Manager M

5/10/15 min

SMA Inverter Manager

(tick) Inverters

(tick) Weather sensors

(tick) Battery system

(tick) Meter/power analyzer

(tick) FTP

Data format: TXT

(tick) Encrypted connection

(tick) Configuration via portal

5/10/15 min

SolarEdge API

(tick) Inverters

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

Data format: JSON

Import configuration: SolarEdge API

5/15 min

Solar-Log 1000/2000/Base 2000

(tick) Inverters

(tick) Weather sensors

(tick) FTP

Data format: CSV/JS

Import configuration: Solar-Log

5/10/15 min

SOL Connect Center

(tick) Inverters

(tick) Weather sensors

(tick) FTP

Data format: XML

(tick) Encrypted connection

5/10/15min

SolisCloud API

(tick) Inverters

(tick) Weather sensors

(tick) Battery system

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

Data format: JSON

5 min

Streem API

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

Data format: JSON

(tick) Encrypted connection

60 min

Sungrow iSolarCloud API

(tick) Inverters

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) HTTP/ Rest-API

Data format: JSON

(tick) Encrypted connection

Import configuration: Sungrow iSolarCloud API

5 min

Sunways PT/AT series

(tick) Inverters

(tick) Weather sensors

(tick) Email

Data format: TXT/CSV

Import configuration: SUNWAYS PT/AT series

15 min

TMEIC

(tick) Inverters

(tick) String monitoring

(tick) Weather sensors

(tick) Meter/power analyzer

(tick) FTP

Data format: CSV

5/10/15 min

Webdyn

(tick) Inverters

(tick) FTP

Data format: INI/DAT

Import configuration: Webdyn

5/10/15 min