Set up a KOSTAL Piko inverter
General tips
-
Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.
-
The data source name can be freely selected. For recommendations, see our Naming guideline.
-
Set the same measuring interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.
-
To ensure that the data source measuring interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.
-
We recommend ticking the check box Automatic device creation to ensure that VCOM automatically creates any new devices found during each data import.
-
If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.
Data loggers only
-
For data loggers, update the firmware to the latest version prior to configuration.
-
For data loggers, any import that uses FTP can also use SFTP. The access data, such as the FTP server address, user name, and password remain identical. Only the port changes from port 21 (FTP) to port 2222 (SFTP).
APIs only
-
Each day at midnight, VCOM checks for complete data and requests data from the past 7 days. If there are no limitations from the API and the data is available, the gaps will be filled.
Configuration details
|
Protocol |
HTTP |
|---|---|
|
File format |
DAT |
|
Measuring interval |
5 min |
|
Server |
|
|
Port |
80 |
Configuration: Inverter
-
Connect to the web interface of the Kostal Piko inverter. If you do not know the IP address, call up the web interface using the serial number (http: // [SERIALNUMBER])
-
Enter your login information. Factory setting:
Username: pvserver
Password: pvwr -
Enter the identifier P202L in the Portal Code field. Select Apply.
-
Enter the words go online in the Portal Code field. Select Apply.
-
A test transmission will start. If your inverter has already measured yield data, these will be transferred to the VCOM portal within the next five minutes.
-
Switch back to the inverter start page (Info) and close the Internet browser.
-
The setup of your inverter is now complete.
Configuration: VCOM
-
Select Kostal as the device type
Note
-
The inverter normally only sends data to the VCOM portal once per day (approx. 11:00 p.m.).