Set up an SMA Inverter Manager

📗

General tips

  • Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.

  • The data source name can be freely selected. For recommendations, see our Naming guideline.

  • Set the same aggregation interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.

  • To ensure that the data source aggregation interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.

  • We strongly recommend ticking the check box Automatic device creation to ensure that VCOM automatically creates any new devices found during each data import.

  • If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.

Data loggers only

  • For data loggers, update the firmware to the latest version prior to configuration.

  • For data loggers, any import that uses FTP can also use SFTP. The access data, such as the FTP server address, user name, and password remain identical. Only the port changes from port 21 (FTP) to port 2222 (SFTP).

APIs only

  • If you experience import issues with the API, please contact the respective API provider first.

  • Each day at midnight, VCOM checks for complete data and requests data from the past 7 days. If there are no limitations from the API and the data is available, the gaps will be filled.

Configuration details

Protocol

FTP

File format

CSV

Measuring interval

Variable: 300 sec/5 min recommended

Server

ftp.sspcdn-a.net

Port

21

Configuration: Data logger
  • Copy the FTP access data specified in the data logger configuration and store them in the SMA Inverter Manager (FTP server, FTP user name, FTP password).

  • Perform a connection test.

Configuration: VCOM
Configure SMA Inverter Manager in VCOM
Configure SMA Inverter Manager in VCOM
  1. Go to icon-wrench1.png System settings > icon-database-insert.png Data sources > Select SMA Inverter Manager.

  2. Select Add.

  3. Enter the Data logger name and Aggregation interval.

  4. Select Register new data logger.

  5. New fields appear. Enter the FTP User name, Password, and Server.

  6. Select Save settings.

    Configure SMA Inverter Manager in VCOM
    Configure an SMA Inverter Manager in VCOM
  7. To ensure that the datalogger serial and measuring interval were set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM.

sma inv manager vcom 2-20241108-084402.jpeg

The data logger is registered.