Last modified:
You can view the realtime data of the devices connected to your blue'Log under Cockpit > Realtime values. Realtime values are a live measurement: the data is neither stored nor exported and is only displayed on the blue'Log web interface.
View realtime values
Prerequisites
-
At least one device is installed on your blue'Log.
Steps
-
Go to Cockpit > Realtime values.
-
If there is more than one device installed on your blue'Log, select the device category you want to view, for example Inverters. You can view multiple device categories simultaneously.
-
Select the device(s) you want to view by ticking the checkboxes. Select all to select all devices of a category.
-
Select the value(s) you want to view by ticking the checkboxes. Select all to select all values of a category.
-
Select View to display the values. The values will be displayed in the Realtime values area.
Note
Cos phi (also known as cos φ or power factor) is a calculated value.
When multiple real meters are combined into a virtual meter, the cos phi value is calculated based on the following formula:
Variables
-
P is the measured active power sum of all phases
-
Q is the measured reactive power sum of all phases
-
tan-1 represents the arctangent function
-
sgn(Q) represents the sign of Q, so if Q is underexcited it is -1, otherwise it is 1
Any measured values from the individual meters are ignored.
Check communication between blue'Log and another device
You can check how well communication is working between the blue'Log and a device using the Telegrams received and Telegrams transmitted checkboxes under Values. The transmitted and received telegram counts should match, confirming that commands are successfully sent and acknowledged. A mismatch may signal a device issue or require adjustments to the read delay or timeout settings.
Prerequisite
-
At least one device is installed on your blue'Log.
-
The device is connected via RS485 or Ethernet
Steps
-
Go to Cockpit > Realtime values.
-
If multiple devices are installed, select the relevant device category (for exmaple Inverters). You can view multiple categories at once.
-
Select the device(s) by ticking the checkboxes, or choose Select all to include all devices in a category.
-
Tick Telegrams received and Telegrams transmitted under Values.
-
Click View to display the telegrams in the Realtime values area.
-
If transmitted and received telegram counts do not match, indicating a potential issue, contact Support for assistance.