SMA Webbox / Cluster controller

Set up an SMA Webbox / Cluster controller

General tips

  • Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.

  • The data source name can be freely selected. For recommendations, see our Naming guideline.

  • Set the same measuring interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.

  • To ensure that the data source measuring interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.

  • If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.

Configuration details

Protocol

FTP

File format

XML (recommended) / CSV

Measuring interval

Variable / 300 seconds (recommended)

Server

ftp.sspcdn-a.net

Port

21

Configuration: Data logger
  • Disable the local language settings for measured data

    SMA Webbox Cluster controller_Disable local language settings for measured data

    SMA Webbox / Cluster controller: Disable local language settings for measured data

  • Check the settings for summer, winter, and time zones

  • Copy the FTP access data specified in the data logger configuration and store them in the SMA Inverter Manager (FTP server, FTP user name, FTP password).

  • Perform a connection test.

    SMA Webbox Cluster controller_Perform connection test

    SMA Webbox / Cluster controller: Perform connection test

Configuration: VCOM
  1. Set SMA Cluster Controller / Webbox as the measured value system.

  2. Enter the data logger serial number and select local measuring interval settings.

  3. Define the incoming timestamp as local or UTC time. Default is local time.

sma webbox vcom-20241108-090029.jpeg

Configure SMA Webbox / Cluster controller in VCOM