Skip to main content
Skip table of contents

SMA Data Manager M

Set up an SMA Data Manager M

General tips

  • Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.

  • The data source name can be freely selected. For recommendations, see our Naming guideline.

  • Set the same measuring interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.

  • To ensure that the data source measuring interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.

  • If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.

Configuration details

Protocol

FTP

File format

XML

Measuring interval

Variable: 300 sec/5 min recommended

Server

ftp.sspcdn-a.net

Port

21

Data Manager serial number

SMA Data Manager Location of serial number

Configuration: Data logger
  1. Copy the FTP access data specified in the data logger configuration and store them in the SMA Inverter Manager (FTP server, FTP user name, FTP password).

    SMA Data Manager Navigate to settings

    SMA Data Manager: Navigate to FTP push settings


    SMA Data Manager_FTP Push

    SMA Data Manager: FTP Push and transmission interval

  2. Perform a connection test.

Configuration: VCOM
Configure SMA Data Manager in VCOM

Configure SMA Data Manager in VCOM