Set up an LTi PV-Master I/II inverter

General tips

  • Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.

  • The data source name can be freely selected. For recommendations, see our Naming guideline.

  • Set the same measuring interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.

  • To ensure that the data source measuring interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.

  • If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.

Configuration details

Protocol

FTP

File format

XML / CSV

Measuring interval

Variable: 300 sec/5 min recommended

Server

https://api1.sspcdn-a.net/

Port

21

Configuration: Inverter
  1. On the LTi PVMaster, enter the FTP access data. Pay attention to upper and lower case letters.

  2. On the LTi PVMaster, set the system date, time, and offset.

  3. Check the IP settings (gateway, DNS server, etc.) for correctness.

  4. Perform a connection test on the LTi inverter to test the FTP push functionality.

Configuration: VCOM
  • Select LTi PVMaster I or LTi PVMaster II as the device type.

Configure LTi PVMaster in VCOM

Configure LTi PVMaster in VCOM