KOSTAL Piko inverter
Set up a KOSTAL Piko inverter
General tips
Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.
The data source name can be freely selected. For recommendations, see our Naming guideline.
Set the same measuring interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.
To ensure that the data source measuring interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.
If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.
Configuration details
Protocol | HTTP |
---|---|
File format | DAT |
Measuring interval | Variable: 300 sec/5 min recommended |
Server | |
Port | 80 |
Configuration: Inverter
Connect to the web interface of the Kostal Piko inverter. If you do not know the IP address, call up the web interface using the serial number (http: // [SERIALNUMBER])
Enter your login information. Factory setting:
Username: pvserver
Password: pvwrEnter the identifier P202L in the Portal Code field. Select Apply.
Enter the words go online in the Portal Code field. Select Apply.
A test transmission will start. If your inverter has already measured yield data, these will be transferred to the VCOM portal within the next five minutes.
Switch back to the inverter start page (Info) and close the Internet browser.
The setup of your inverter is now complete.
Configuration: VCOM
Select Kostal as the device type
Note
The inverter normally only sends data to the VCOM portal once per day (approx. 11:00 p.m.).