Set up a HUAWEI FusionSolar API

General tips

  • Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.

  • The data source name can be freely selected. For recommendations, see our Naming guideline.

  • Set the same measuring interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.

  • To ensure that the data source measuring interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.

  • If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.

Configuration details

Protocol

Pull via HTTPS

File format

JSON

Measuring interval

Variable: 300 sec/5 min recommended

Query interval

15 min

User name

Huawei FusionSolar user name

Password

Huawei FusionSolar password

Station code

Huawei FusionSolar station code

huawei station code-20241114-103624.png

Configuration: API

  • Set up user for NorthBound (API) in the FusionSolar UI. Select System > Company Management > System > Northbound Management.

  • Identify the system codes. These will be equivalent to the system keys when configuring VCOM

Configuration: VCOM

  1. In the VCOM system configuration, select Data sourcesData logger overview > select Huawei FusionSolar API.

  2. Select Add.

    image-20241114-102041.png
  3. Insert the Huawei User name, System code, and Station codes.

    image-20241114-102143.png
  4. Select Save settings.