HUAWEI FusionSolar API
Set up a HUAWEI FusionSolar API
General tips
Have the data source (data logger, etc.) serial number on hand. When entering the serial number, pay attention to uppercase and lowercase letters and empty spaces.
The data source name can be freely selected. For recommendations, see our Naming guideline.
Set the same measuring interval for all data sources in the system to ensure charts are accurately displayed in VCOM. This is used to normalize uneven timestamps and aggregate smaller recorded intervals into larger ones.
To ensure that the data source measuring interval has been set correctly in VCOM, open an imported file in the Data logger overview portlet in VCOM and check the timestamps.
If possible, perform a connection test once you have completed the configuration in both VCOM and the data source.
Configuration details
Protocol | Pull via HTTPS |
---|---|
File format | JSON |
Measuring interval | Variable: 300 sec/5 min recommended |
Query interval | 15 min |
User name | Huawei FusionSolar user name |
Password | Huawei FusionSolar password |
Station code | Huawei FusionSolar station code ![]() |
Configuration: API
Set up user for NorthBound (API) in the FusionSolar UI. Select System > Company Management > System > Northbound Management.
Identify the system codes. These will be equivalent to the system keys when configuring VCOM
Configuration: VCOM
In the VCOM system configuration, select Data sources > Data logger overview > select Huawei FusionSolar API.
Select Add.
Insert the Huawei User name, System code, and Station codes.
Select Save settings.